E2618-O2

Oxygen Transmitter
E2618-O2
Features
  • Electrochemical sensor
  • Range 0...25 %vol O2
  • Resolution 0,01 %vol O2
  • 2 × 4-20 mA or 0-10 V, RS485
Description

Oxygen transmitter E2618-O2 is a member of new PluraSens® family of multifunctional measurement instruments.

The instrument may be used to prevent critical decrease of O2 concentration as well as to control the absence of the oxygen in gas mixtures.

The instrument utilises a fully calibrated and temperature compensated gas sensor with excellent repeatability, stability and long lifetime. 

Two analog outputs and RS485 digital interface with industry standard Modbus RTU protocol can be used to connect the transmitter to safety or building automation systems.


Technical Data
Calibration oxygen O2
Sensor type electrochemical
Sampling method diffusion
Detection range 0...25 %vol O2
Resolution 0,01 %vol O2
Sensor lifetime > 2 years
Power supply 12...36 VDC (default)
24 VAC as option
Digital interface RS485, Modbus RTU protocol
Analog outputs 2 × 4-20 mA / 0-10 V, user settable
Enclosure grey ABS plastic, wall mount, IP65
Dimensions H82 × W80 × D55 mm
Operating conditions -30...+50 °C, 15...90 %RH