E2608-CO2

Carbon Dioxide Detector
E2608-CO2
Features
  • Stable long-life photoacoustic or optical NDIR sensor
  • Range 0...10 000 ppm / 40 000 ppm / 5 %vol CO2
  • Resolution 1 ppm / 10 ppm / 0.01 %vol CO2
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485
Description

Carbon dioxide detector-transmitter E2608-CO2 is a member of new PluraSens® family of multifunctional measurement instruments.

Applications include HVAC and air quality control in public, office and industrial buildings, greenhouses, underground parkings, boiler houses, and other confined spaces, where potentially toxic concentration of carbon dioxide can accumulate.

The instrument utilises a fully calibrated and temperature compensated photoacoustic or optical NDIR gas sensor with excellent repeatability, stability and long lifetime. Ambient pressure compensation (in the range 0,5...2 bar of absolute pressure) is available as an option.

Two relays with closing contact may be used for remote signalling or ventilation control. Two alarm set-points are user settable.

Two analog outputs and RS485 digital interface with industry standard Modbus RTU protocol can be used to connect the detector to safety or building automation systems.


Technical Data
Calibration carbon dioxide CO2
Sensor type photoacoustic
optical NDIR
Sampling method diffusion
Detection range 0...10 000 ppm (10K) CO2
0...40 000 ppm (40K) CO2
0...5 %vol (50KN) CO2
up to 100 %vol CO2 on request
Resolution 1 ppm for 10K
10 ppm for 40K
0.01%vol for 50KN
Sensor lifetime up to 10 years for 10K/40K
up to 5 years for 50KN
Power supply 12...36 VDC (default),
24 VAC or 230 VAC as options
Digital interface RS485, Modbus RTU protocol
Analog outputs 2 × 4-20 mA / 0-10 V, user settable
Output relays 2 × SPST relays (closing contact),
Enclosure grey ABS plastic, wall mount, IP65
Dimensions H85 × W82 × D55 mm
Operating conditions -40...+60 °C, 0...100 %RH


Similar Products


E2608-VOC - Solvent Vapors Detector
E2608-VOC - Solvent Vapors Detector
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...1000 ppm
  • Resolution 0,1% LEL or 1 ppm
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2608-CH4 - Methane Detector
E2608-CH4 - Methane Detector
  • Stable long-life metal-oxide / pellistor sensor
  • Range 0...100% LEL CH4
  • Resolution 0,1 / 1 % LEL CH4
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2608-NH3-E - Ammonia Detector
E2608-NH3-E - Ammonia Detector
  • Stable long-life electrochemical sensor
  • Range 0...100 / 0...300 / 0...1000 / 0...5 000 ppm NH3
  • Resolution 1 ppm NH3
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2608-CO - Carbon Monoxide Detector
E2608-CO - Carbon Monoxide Detector
  • Stable long-life electrochemical sensor
  • Range 0...300 or 0...1000 ppm CO
  • Resolution 1 ppm CO
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2608-O2 - Oxygen Detector
E2608-O2 - Oxygen Detector
  • Electrochemical sensor
  • Range 0...25 %vol O2
  • Resolution 0,01 %vol O2
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2608-NO2 - Nitrogen Dioxide Detector
E2608-NO2 - Nitrogen Dioxide Detector
  • Stable long-life electrochemical sensor
  • Range 0...20 or 0...200 ppm NO2
  • Resolution 0,1 ppm or 1 ppm NO2
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2608-H2S - Hydrogen Sulfide Detector
E2608-H2S - Hydrogen Sulfide Detector
  • Stable long-life electrochemical sensor
  • Range 0...100 or 0...2000 ppm H2S
  • Resolution 1 ppm H2S
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2608-LEL - Combustible Gas Detector
E2608-LEL - Combustible Gas Detector
  • Stable long-life metal-oxide / pellistor sensor
  • Range 0...100% LEL
  • Resolution 0,1 / 1 % LEL
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2608-HFC - Refrigerants Detector
E2608-HFC - Refrigerants Detector
  • Stable long-life metal-oxide sensor
  • Ranges 0...1000 / 0...2500 ppm halocarbon gas
  • Resolution 1 ppm halocarbon gas
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2608-O3 - Ozone Detector
E2608-O3 - Ozone Detector
  • Stable long-life electrochemical sensor
  • Range 0...5 ppm or 0...1 ppm O3
  • Resolution 0,01 ppm O3
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2608-C2H4 - Ethylene Detector
E2608-C2H4 - Ethylene Detector
  • Humidity compensated electrochemical sensor
  • Range 0...10 / 0...200 / 0...1500 ppm C2H4
  • Resolution 0,1 / 1 / 1 ppm C2H4
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2608-Cl2 - Chlorine Detector
E2608-Cl2 - Chlorine Detector
  • Stable long-life electrochemical sensor
  • Range 0...10 ppm Cl2
  • Resoluton 0,1 ppm Cl2
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2608-SO2 - Sulfur Dioxide Detector
E2608-SO2 - Sulfur Dioxide Detector
  • Stable long-life electrochemical sensor
  • Range 0...50 or 0...2000 ppm SO2
  • Resolution 0,1 ppm or 1 ppm SO2
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2608-NO - Nitric Oxide Detector
E2608-NO - Nitric Oxide Detector
  • Stable long-life electrochemical sensor
  • Detection range 0...250 ppm NO
  • Resolution 1 ppm NO
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2608-ETO - Ethylene Oxide Detector
E2608-ETO - Ethylene Oxide Detector
  • Stable long-life electrochemical sensor
  • Range 0...20 or 0...100 ppm C2H4O
  • Resolution 0,1 ppm or 1 ppm C2H4O
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2608-PID - Solvent Vapors Detector
E2608-PID - Solvent Vapors Detector
  • Highly sensitive Photo Ionization Detector
  • Range 0...40 or 0...200 ppm isobutylene
  • Resolution 0,01 ppm or 1 ppm isobutylene
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2608-NH3-P - Ammonia Detector
E2608-NH3-P - Ammonia Detector
  • Stable long-life pellistor gas sensor
  • Range 0...15% vol. (0…100% LEL)
  • Resolution 0.1% vol. or 1% LEL
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485
  • Wall-mount or duct-mount version
  • Attached or remote sensor