Features
  • For measuring temperatures -50...+500 °C
  • Pt100, Pt1000, PTC1000 or NTC sensors
  • Available in 2-, 3- or 4-wire circuit
  • Silicone, teflon or fiberglass insulated cable
  • Quick and easy installation
  • Double RTD sensing element option
Description

ET241 series surface temperature sensors are designed for measuring temperatures on closed pipe systems or other round or flat surfaces. The sensor can be conveniently fixed with a hose clamp or M3 screw. Mounting with hose clamps avoids any mechanical preparation of the measurement site.

Indirect temperature measurement avoids disturbing flow of the medium and the measurement object is hardly affected by the low thermal mass of the sensor. On the other hand, lack of pressure and chemical effects ensures longer lifespan of the sensor.

It must be considered that large differences in temperature between the measurement medium and surroundings have a direct effect on the measurement result. In such cases, additional insulation around the sensor and the cable in at least 10 cm range is advisable. To improve heat transfer from surface to the sensor, heat-conductive paste can be supplied.

4-20 mA transmitter possibility.


Technical Data
Sensing element Pt100, Pt1000, PTC1000 or NTC sensor
Measurement range -50...+250 °C or -50...+500 °C
Protection tube A4 / AISI316L stainless steel
Dimensions Ø4 mm or 6 mm, L50 mm
Protection class IP55 as standard, IP68 on request
Cable 3 wires, red-red-white; 2 wires red-white
Maximum cable temperature (continuous / peak) Silicone insulated 180 / 230 °C
fluoroplast insulated 260 / 310 °C
Fiberglass insulated 480 / 530 °C
Mounting Hose clamp or M3 screw


Similar Products


ET211 - Screw-in temperature probe with cable
ET211 - Screw-in temperature probe with cable
  • For temperature measurement -50...+500 °C
  • Pt100, Pt1000, PTC1000 or NTC sensors
  • Available in 2-wire and 3-wire circuit
  • A4 / AISI316L stainless steel body

ET201 - Insertion temperature probes with cable
ET201 - Insertion temperature probes with cable
  • Pt100, Pt1000, PTC or NTC sensor
  • A4 / AISI316L steel protection tube 
  • Tube Ø4 or Ø6 mm, length 30...1000 mm
  • Silicone, fluoroplast or fiberglass cable

ET204 - HVAC/R temperature sensor
ET204 - HVAC/R temperature sensor
  • Pt1000, Ni1000 RTD or NTC thermistor
  • -40...+105 °C operation
  • Stainless steel or plastic protection tube
  • Plastic flange with rubber grommet
  • Two-wire PVC insulated cable

ET243 - Pipe surface temperature sensor
ET243 - Pipe surface temperature sensor
  • Operating range -40...+80 °C or -30...+105 °C
  • Pt1000 sensor
  • For pipes Ø16...60 mm
  • PVC insulated cable