E2608-H2S

Hydrogen Sulfide Detector
E2608-H2S
Features
  • Stable long-life electrochemical sensor
  • Range 0...100 or 0...2000 ppm H2S
  • Resolution 1 ppm H2S
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485
Description

Hydrogen sulfide detector-transmitter E2608-H2S is a member of new PluraSens® family of multifunctional measurement instruments.

Applications include sewerage systems, labs, industrial premises and other confined spaces, where potentially toxic concentration of hydrogen sulfide can accumulate.

The instrument utilises a fully calibrated and temperature compensated electrochemical gas sensor with excellent repeatability, stability and long lifetime.

Two relays with closing contact may be used for remote signalling or ventilation control. Two alarm set-points are user settable.

Two analog outputs and RS485 digital interface with industry standard Modbus RTU protocol can be used to connect the detector to safety or building automation systems.


Technical Data
Calibration hydrogen sulfide H2S
Sensor type electrochemical
Sampling method diffusion
Detection range 0...100 ppm H2S
0...2000 ppm H2S
other ranges on request
Resolution 1 ppm H2S
Sensor lifetime > 2 years
Power supply 12...36 VDC (default),
24 VAC or 230 VAC as options
Digital interface RS485, Modbus RTU protocol
Analog outputs 2 × 4-20 mA / 0-10 V, user settable
Output relays 2 × SPST relays (closing contact),
250 VAC / 30 VDC, 5 A max
Default alarm set-points 10 ppm / 20 ppm H2S
Enclosure grey ABS plastic, wall mount, IP65
Dimensions H85 × W82 × D55 mm
Operating conditions -30...+50 °C, 15...90 %RH for 100 ppm range
-40...+50 °C, 15...90 %RH for 2000 ppm range


Similar Products


E2618-H2S - Hydrogen Sulfide Transmitter
E2618-H2S - Hydrogen Sulfide Transmitter
  • Stable long-life electrochemical sensor
  • Range 0...100 or 0...2000 ppm H2S
  • Resolution 1 ppm H2S
  • 2 × 4-20 mA or 0-10 V, RS485

E2638-H2S - Hydrogen Sulfide Detector
E2638-H2S - Hydrogen Sulfide Detector
  • Stable long-life electrochemical sensor
  • Range 0...100 or 0...2000 ppm H2S
  • Resolution 1 ppm H2S
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2648-H2S - Hydrogen Sulfide Detector
E2648-H2S - Hydrogen Sulfide Detector
  • Stable long-life electrochemical sensor
  • Range 0...100 or 0...2000 ppm H2S
  • Resolution 1 ppm H2S
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2670-H2S - Flameproof Hydrogen Sulfide Detector
E2670-H2S - Flameproof Hydrogen Sulfide Detector
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life electrochemical cell
  • Ranges 0...100 ppm, 0...2000 ppm H2S
  • Resolution 1 ppm H2S
  • Two SPST relays option
  • 2 × 4-20 mA / 0-10 V, RS485