E2630-LEL

Combustible Gas Detector
E2630-LEL
Features
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL
  • Two SPDT relays
  • UART digital interface
Description

Combustible gas detector E2630-LEL is an easy-to-use instrument intended for underground parkings, boiler houses, kitchens, and other confined spaces, where potentially explosive concentration of combustible gases can accumulate.

The instrument utilises a fully calibrated metal-oxide gas sensor with excellent repeatability, stability and long lifetime.

Two relays with switch-over contact may be used for remote signalling or ventilation control. Flashing LED and internal buzzer give visual and sound alarms.


Technical Data
Detected gases hydrogen, methane, acetylene, propane, butane
Default calibration methane CH4
Sensor type metal-oxide semiconductor
Sampling method diffusion
Detection range 0...100% LEL
Sensor lifetime > 5 years
Power supply 24 VDC/AC ±20% (default)
or 230 VAC (optional)
Digital interface UART
Output relays 2 x SPDT relays (switch-over contact)
250 VAC / 30 VDC, 5 A max
Alarms blinking LED, buzzer 85 dB
Default alarm set-points 10% LEL / 25% LEL
Enclosure grey ABS plastic, wall mount, IP65
Dimensions H90 × W145 × D55 mm
Operating conditions -40...+70 °C, <95 %RH (non condensing)


Similar Products


E2611-CH4 - Methane Detector
E2611-CH4 - Methane Detector
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL CH4
  • Resolution 0,1% LEL CH4
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2610-LEL - Combustible Gas Detector
E2610-LEL - Combustible Gas Detector
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL
  • Two SPDT relays
  • UART digital interface

E2608-CH4 - Methane Detector
E2608-CH4 - Methane Detector
  • Stable long-life metal-oxide / pellistor sensor
  • Range 0...100% LEL CH4
  • Resolution 0,1 / 1 % LEL CH4
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2608-LEL - Combustible Gas Detector
E2608-LEL - Combustible Gas Detector
  • Stable long-life metal-oxide / pellistor sensor
  • Range 0...100% LEL
  • Resolution 0,1 / 1 % LEL
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2618-CH4 - Methane Transmitter
E2618-CH4 - Methane Transmitter
  • Stable long-life metal-oxide / pellistor sensor
  • Range 0...100% LEL CH4
  • Resolution 0,1 / 1 % LEL CH4
  • 2 × 4-20 mA or 0-10 V, RS485

E2618-LEL - Combustible Gas Transmitter
E2618-LEL - Combustible Gas Transmitter
  • Stable long-life metal-oxide / pellistor gas sensor
  • Range 0...100% LEL
  • Resolution 0,1 / 1 % LEL
  • Wall mount or duct mount version
  • Attached or remote sensor
  • 2 × 4-20 mA or 0-10 V, RS485

E2638-CH4 - Methane Detector
E2638-CH4 - Methane Detector
  • Stable long-life metal-oxide / pellistor sensor
  • Range 0...100% LEL CH4
  • Resolution 0,1 / 1 % LEL CH4
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2638-LEL - Combustible Gas Detector
E2638-LEL - Combustible Gas Detector
  • Stable long-life metal-oxide / pellistor sensor
  • Range 0...100% LEL
  • Resolution 0,1 / 1 % LEL
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2611-LEL - Combustible Gases Detector
E2611-LEL - Combustible Gases Detector
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL
  • Resolution 0,1% LEL
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2648-CH4 - Methane Detector
E2648-CH4 - Methane Detector
  • Stable long-life metal-oxide / pellistor sensor
  • Range 0...100% LEL CH4
  • Resolution 0,1 / 1 % LEL CH4
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2648-LEL - Combustible Gas Detector
E2648-LEL - Combustible Gas Detector
  • Stable long-life metal-oxide / pellistor sensor
  • Range 0...100% LEL
  • Resolution 0,1 / 1 % LEL
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2615-LEL - Combustible Gas Transmitter
E2615-LEL - Combustible Gas Transmitter
  • High long-term stability
  • User selectable output 4-20 mA / 0-10 V
  • Range of compact wall mount enclosures
  • Low cost for volume HVAC applications

E2632-CO-CH4 - Two Channel Gas Detectors
E2632-CO-CH4 - Two Channel Gas Detectors
  • Simultaneous detection of two gases
  • Accurate and stable measurement
  • Wall-mount IP65 protected housing
  • Visual and acoustic alarms
  • Two output relays for alarm / ventilation control

E2670-CH4 - Flameproof Methane Detector
E2670-CH4 - Flameproof Methane Detector
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life metal-oxide / pellistor sensor
  • Range 0...100% LEL CH4
  • Resolution 0,1 / 1 % LEL CH4
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2670-LEL - Flameproof Combustible Gas Detector
E2670-LEL - Flameproof Combustible Gas Detector
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life metal-oxide / pellistor sensor
  • Range 0...100% LEL
  • Resolution 0,1 / 1 % LEL
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2660-CO-LEL - Combustible Gases Transmitter
E2660-CO-LEL - Combustible Gases Transmitter
  • Simultaneous CO and combustible gases monitoring
  • RS485 Modbus RTU digital interface
  • Two analog outputs 4-20 mA / 0-10 V
  • Easy-to-install IP65 protected enclosure
  • Attached or remote sensor
  • Two SPST relays option
  • Acoustic alarm option