E2632-CO-CH4

Two Channel Gas Detectors
E2632-CO-CH4
Features
  • Simultaneous detection of two gases
  • Accurate and stable measurement
  • Wall-mount IP65 protected housing
  • Visual and acoustic alarms
  • Two output relays for alarm / ventilation control
Description
Two channel E2632-CO-CH4 gas detector is a compact and easy-to-use instrument for the simultaneous measurement of two gases in boiler rooms.

The instrument utilizes novel fully calibrated and temperature compensated gas sensors with excellent repeatability, stability, and long lifetime.

Two relays RE1 and RE2 with switching contacts can be used to control alarm sirens, ventilation fans, shut-off valves, or other actuators for each sensor. The detector is equipped with a visual and acoustic alarm for each sensor. 24 VAC or 230 VAC power supply options are available.


Technical Data
Sensor type Depending on detected gases available are
Metal oxide sensors,
Electrochemical sensors
Sampling method Diffusion
Power supply 24 VDC/AC ±20% (default)
or 230 VAC (optional)
Digital interface UART
Relay outputs 2 relays with switch-over contact per sensor,
2 × SPDT, max 5 A, 30 VDC / 250 VAC
Alarms Blinking LEDs, buzzers 85 dB
Enclosure Grey ABS, wall mount, protection class IP65
Dimensions H123 × W201 × D55 mm
Operating conditions 15...95 %RH
Atmospheric pressure ±10%
Non-Atex rated areas
The temperature depends on the sensor.


Similar Products


E2611-CH4 - Methane Detector
E2611-CH4 - Methane Detector
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL CH4
  • Resolution 0,1% LEL CH4
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2610-LEL - Combustible Gas Detector
E2610-LEL - Combustible Gas Detector
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL
  • Two SPDT relays
  • UART digital interface

E2608-CH4 - Methane Detector
E2608-CH4 - Methane Detector
  • Stable long-life metal-oxide / pellistor sensor
  • Range 0...100% LEL CH4
  • Resolution 0,1 / 1 % LEL CH4
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2608-LEL - Combustible Gas Detector
E2608-LEL - Combustible Gas Detector
  • Stable long-life metal-oxide / pellistor sensor
  • Range 0...100% LEL
  • Resolution 0,1 / 1 % LEL
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2618-CH4 - Methane Transmitter
E2618-CH4 - Methane Transmitter
  • Stable long-life metal-oxide / pellistor sensor
  • Range 0...100% LEL CH4
  • Resolution 0,1 / 1 % LEL CH4
  • 2 × 4-20 mA or 0-10 V, RS485

E2618-LEL - Combustible Gas Transmitter
E2618-LEL - Combustible Gas Transmitter
  • Stable long-life metal-oxide / pellistor gas sensor
  • Range 0...100% LEL
  • Resolution 0,1 / 1 % LEL
  • Wall mount or duct mount version
  • Attached or remote sensor
  • 2 × 4-20 mA or 0-10 V, RS485

E2630-LEL - Combustible Gas Detector
E2630-LEL - Combustible Gas Detector
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL
  • Two SPDT relays
  • UART digital interface

E2638-CH4 - Methane Detector
E2638-CH4 - Methane Detector
  • Stable long-life metal-oxide / pellistor sensor
  • Range 0...100% LEL CH4
  • Resolution 0,1 / 1 % LEL CH4
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2638-LEL - Combustible Gas Detector
E2638-LEL - Combustible Gas Detector
  • Stable long-life metal-oxide / pellistor sensor
  • Range 0...100% LEL
  • Resolution 0,1 / 1 % LEL
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2611-LEL - Combustible Gases Detector
E2611-LEL - Combustible Gases Detector
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL
  • Resolution 0,1% LEL
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2648-CH4 - Methane Detector
E2648-CH4 - Methane Detector
  • Stable long-life metal-oxide / pellistor sensor
  • Range 0...100% LEL CH4
  • Resolution 0,1 / 1 % LEL CH4
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2648-LEL - Combustible Gas Detector
E2648-LEL - Combustible Gas Detector
  • Stable long-life metal-oxide / pellistor sensor
  • Range 0...100% LEL
  • Resolution 0,1 / 1 % LEL
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2615-LEL - Combustible Gas Transmitter
E2615-LEL - Combustible Gas Transmitter
  • High long-term stability
  • User selectable output 4-20 mA / 0-10 V
  • Range of compact wall mount enclosures
  • Low cost for volume HVAC applications

E2670-CH4 - Flameproof Methane Detector
E2670-CH4 - Flameproof Methane Detector
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life metal-oxide / pellistor sensor
  • Range 0...100% LEL CH4
  • Resolution 0,1 / 1 % LEL CH4
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2670-LEL - Flameproof Combustible Gas Detector
E2670-LEL - Flameproof Combustible Gas Detector
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life metal-oxide / pellistor sensor
  • Range 0...100% LEL
  • Resolution 0,1 / 1 % LEL
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2660-CO-LEL - Combustible Gases Transmitter
E2660-CO-LEL - Combustible Gases Transmitter
  • Simultaneous CO and combustible gases monitoring
  • RS485 Modbus RTU digital interface
  • Two analog outputs 4-20 mA / 0-10 V
  • Easy-to-install IP65 protected enclosure
  • Attached or remote sensor
  • Two SPST relays option
  • Acoustic alarm option