E2608-VOC

Solvent Vapors Detector
E2608-VOC
Features
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...1000 ppm
  • Resolution 0,1% LEL or 1 ppm
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485
Description

Volatile Organic Compounds detector-transmitter E2608-VOC is a member of new PluraSens® family of multifunctional measurement instruments which is intended for detection of various solvent vapors, e.g. toluene, xylene, ethanol.

Applications include storages, painting chambers and other confined spaces, where toxic or potentially explosive concentration of volatile organic compounds can accumulate.

The instrument utilises a fully calibrated metal-oxide semiconductor gas sensor with excellent repeatability, stability and long lifetime.

According to user's preferences the detector can be ordered for either fire prevention (range 0...100% LEL) or for toxicity prevention (range 0...1000 ppm).

Two relays with closing contact may be used for remote signalling or ventilation control. Two alarm set-points are user settable.

Two analog outputs and RS485 digital interface with industry standard Modbus RTU protocol can be used to connect the detector to safety or building automation systems.


Technical Data
Detected vapors acetone, ethanol, toluene, xylene etc
Default calibration toluene
Sensor type metal-oxide semiconductor
Sampling method diffusion
Detection range 0...100% LEL (flammable range)
0...1000 ppm (toxic range)
Resolution 0,1% LEL for LEL range
1 ppm for ppm range
Sensor lifetime > 5 years
Power supply 12...36 VDC (default),
24 VAC or 230 VAC as options
Digital interface RS485, Modbus RTU protocol
Analog outputs 2 × 4-20 mA / 0-10 V, user settable
Output relays 2 × SPST relays (closing contact),
250 VAC / 30 VDC, 5 A max
Default alarm set-points 20% LEL / 50% LEL
100 ppm / 300 ppm
Enclosure grey ABS plastic, wall mount, IP65
Dimensions H85 × W82 × D55 mm
Operating conditions -30...+70 °C, < 95 %RH


Similar Products


E2610-VOC - Solvent Vapor Detector
E2610-VOC - Solvent Vapor Detector
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...500 ppm
  • Resolution 0,1% LEL or 1 ppm
  • Two SPDT relays
  • UART digital interface

E2611-VOC - Solvent Vapor Detector
E2611-VOC - Solvent Vapor Detector
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...1000 ppm
  • Resolution 0,1% LEL or 1 ppm
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2618-VOC - Solvent Vapors Transmitter
E2618-VOC - Solvent Vapors Transmitter
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...1000 ppm
  • Resolution 0,1% LEL or 1 ppm
  • 2 × 4-20 mA or 0-10 V, RS485

E2630-VOC - Solvent Vapor Detector
E2630-VOC - Solvent Vapor Detector
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...500 ppm
  • Resolution 0,1% LEL or 1 ppm
  • Two SPDT relays
  • UART digital interface

E2638-VOC - Solvent Vapors Detector
E2638-VOC - Solvent Vapors Detector
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...1000 ppm
  • Resolution 0,1% LEL or 1 ppm
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2608-PID - Solvent Vapors Detector
E2608-PID - Solvent Vapors Detector
  • Highly sensitive Photo Ionization Detector
  • Range 0...40 or 0...200 ppm isobutylene
  • Resolution 0,01 ppm or 1 ppm isobutylene
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

E2618-PID - Solvent Vapors Transmitter
E2618-PID - Solvent Vapors Transmitter
  • Highly sensitive Photo Ionization Detector
  • Range 0...40 or 0...200 ppm isobutylene
  • Resolution 0,01 ppm or 1 ppm isobutylene
  • 2 × 4-20 mA or 0-10 V, RS485

E2638-PID - Solvent Vapors Detector
E2638-PID - Solvent Vapors Detector
  • Highly sensitive Photo Ionization Detector
  • Range 0...40 or 0...200 ppm isobutylene
  • Resolution 0,01 ppm or 1 ppm isobutylene
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2648-PID - Solvent Vapors Detector
E2648-PID - Solvent Vapors Detector
  • Highly sensitive Photo Ionization Detector
  • Range 0...40 or 0...200 ppm isobutylene
  • Resolution 0,01 ppm or 1 ppm isobutylene
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2648-VOC - Solvent Vapors Detector
E2648-VOC - Solvent Vapors Detector
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...1000 ppm
  • Resolution 0,1% LEL or 1 ppm
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2670-PID - Flameproof Solvent Vapors Detector
E2670-PID - Flameproof Solvent Vapors Detector
  • Suitable for ATEX Zones 2 and 22
  • Highly sensitive Photo Ionization Detector
  • Range 0...40 or 0...200 ppm isobutylene
  • Resolution 0,01 ppm or 1 ppm isobutylene
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485

E2670-VOC - Flameproof Solvent Vapors Detector
E2670-VOC - Flameproof Solvent Vapors Detector
  • Suitable for ATEX Zones 2 and 22
  • Stable long-life metal-oxide sensor
  • Range 0...100% LEL or 0...1000 ppm
  • Resolution 0,1% LEL or 1 ppm
  • Two SPST relays option
  • 2 × 4-20 mA or 0-10 V, RS485